LPC96P Low Voltage Integrated Monitoring Device

Application Scenarios:Medium /High Voltage Cabinet,Low Voltage Wiring Cabinet

PRODUCT OVERVIEW

The device in line with the distribution network standardized design 0.4kv Los-voltage switchgear design specification requirements,large screen dot matrix display,using 96,shape and very short gauge depth,especially suitable for applications with narrow installation space,industrial standard wide temperature LCD display,with good high and low temperature display characteristics,the terminal can achieve full power measurement and display,including dynamic alarm,switching input and output status,SOE event recording,compound rate,loop load ratio display,harmonics,etc,support dual communication,transmission output function.It has the function of fault judgment such as short circuit,overload,phase loss,phase sequence,and zero break.It adopts snap-on fixed design to improve the efficiency of cabinet assembly,which is suitable for power industry switchgear distribution panel circuit distribution measurement and control.

KEY FEATURES

  • Overall monitoring
  • High level protection
  • Modular design

 

  

Signal Input

Line

Three phase 3 line, 3 phase, 4 line

Frequency

45~65Hz

Voltage

AC 57.7/100V, 230/380V

Over load:1.2 times the rated value(continuous);

1.4 times rated voltage(10s), 2, times the rated value 1s

Power consumption:< 0.5VA (each line)

Current

AC 1A, 5A

Overload: 1.2 times the rated value (continuous);

20 times the rated value /10 second.

Consumption: < 0.25VA (each line)

Accuracy

V、C、P

0.2

Active

0.5s

Reactive

2

Zero Current (residue)

20mA~1A(±1%); 1A~2A(±2.5%)

Harmonic Sampling

128point/cycle, FFT method,breakdown judging

Power Supply

Range: AC/DC 85V~265V

Consumption: main power consumption≤5VA.

Relay Output

Touch point type: normally open (level output jog mode)

Touch point capacity: AC 250V/3A  DC 30V/3A.

Power Pulse Output

Output mode: optocoupler pulse of open collector

Switch Alue Output

Support dry contact input, DC12V power supply built-in;

Resolution≤5mS

Communication

RS485 interface Modbus-RTU protocol or LT645 stipulation;

Lora, zigbee (wireless communication optional)

Security

Working Pressure

Among APS, voltage signal, current signal AC 2kV/1min;

Working frequency among switch value, pulse output, communication, AC 1kV/1min.

Insulation resistance

Input, output terminal to the chassis>100MΩ.

Electromagnetic

Compatibility

Reach IEC 61000 standard (level 4)

Level of Protection

IP51 (front), IP30 (inside)(except for terminal)

Working Life Designed

10years

Working

Environment

 

Meter Working Temperature: -25℃~+80℃;

LCD Working Temperature: -20℃~+80℃;

Storage Temperature: -40℃~+85℃;

Relative Humidity: ≤99% no condensation;

Elevation: ≤2500m.

 
 

LPC96P Low Voltage Integrated Monitoring Device

铁血殊途 电视剧| 太阳天或下啊天人挤人的物啡比| 神宠大陆| 中国世预赛赛程全部| 旧家普通话水平潮| 社会体育指导员资格证官网| 胡雪岩电视剧| windows自带录屏| xcxoxxcxh d| 韩国电影年轻的嫂子在线观看| 山野涛声| lightroom mac| 同龄人| 属有zn女满品名字围片| 欧陆风云4自建国理念修改| 哈哈| 美女跳舞| 穆里尼奥最新消息新闻| 杨雪仪| bilibii视频下载工具| 11阿布扎比| avdirectorlife| 免费书法体| 蓝猫淘气3000问之恐龙时代 | 望多电影免费观看| 《一滴都不许漏》何泽城林萌| 邓伦电脑壁纸| 乐嘉和孟非| 我是刑警1-40集全免费| 男生把小困困放到女生困里视频| 牙狼炎之刻印| 99炫舞动态头像| 闲鱼有pc端吗| 泰拳王播求比赛视频| b站刺激战场高清版| 《换偶》完整| 中2病也要谈恋爱第一季免费观看